Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.

Product Details
Customization: Available
Type: Fiber Transceiver
Wiring Devices: ODF
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2017

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
  • Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
  • Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
  • Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
  • Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
  • Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
Find Similar Products

Basic Info.

Model NO.
Special Laser for Gas Detection
Certification
ISO, RoHS
Condition
New
Transport Package
Carton
Trademark
Own Brand(Ziguan
Origin
China

Product Description

Exclusive DFB Laser for Precise Gas Detection

Explore our temperature-controlled pigtail laser series, featuring an innovative quantum well structure DFB laser. This series integrates built-in semiconductor refrigeration with an advanced laser welding process, culminating in a butterfly tail fiber package. The result is a compact, small-volume design that is extensively applied in optical fiber communication. The high power and exceptional wavelength stability under precise temperature control through semiconductor refrigeration make this laser indispensable in the realm of optical fiber sensors.

Distinguished Features

State-of-the-art Imported Quantum Well Structure (OMQs) DFB Semiconductor Laser Chip
Unwavering Wavelength Stability
Superior High Output Power
Robust Hermetic Package
Versatile Packaging Options: BF14 Pigtail Type, TF8 Space Type, TO39, and Other Customizations


Diverse Applications

Fiber Optic Gas Detection System for Enhanced Precision
Production and Testing of Passive Components for Gas Detection with Unmatched Accuracy


Rated Limit Operating Conditions:
Parameters Symbol Value Unit
Forward current of laser diode If(LD) 100 mA
Reverse voltage of laser diode Vr(LD) 2 V
Operating current of backlight detector If(PD) 2 mA
Operating voltage of backlight detector Vr(PD) 20 V
Operating current of refrigerator ITEC 2.4 A
Operating voltage of refrigerator VTEC 2.9 V
Operating temperature Topr -20~+70 ºC
Storage temperature Tstg -40~+85 ºC
Lead welding temperature/time Tsld 260/10 ºC/s
 


Technical Parameters: (Measurement Environment Temperature is 25ºC)
Parameters Symbol Condition Min. Typ. Max. Unit
Optical power PO CW 3   10 mW
Threshold current Ith CW 12 18 mA
Operating current Iop CW, 5mW - 100 mA
Operating voltage Vop CW, 5mW 1.5 2.0 V
Slope efficiency η CW, 5mW 0.05 0.1 mW/mA
Peak wavelength λp CW, 5mW@25ºC λc -1 λc λc+ 1 nm
Wavelength stability λs CW,5mW@25ºC -0.1nm   +0.1 dB
Side mode suppression ratio SMSR CW, 5mW 35 nm
Spectral width(20dB) Δλ CW, 5mW 0.2   nm/ºC
Wavelength drift coefficient with temperature Δλ/T Steady operating current   0.1   nm/ºC
Wavelength drift coefficient with current Δλ/I Steady operating temperature   0.01   nm/mA
Thermistor Rth Ttherm = 25ºC 9.5 10 10.5
Important Notice:
In the domain of gas detection, leveraging the absorption spectrum data from HITRAN reveals multiple absorption peaks for identical gases. Clients are advised to select the optimal center wavelength position aligning with their system requirements.

Comprehensive Gas Absorption Reference Table:
 
Gas component Absorption wavelength
O2 761nm,764nm (VCSEL)
HF 1268.7nm,1273nm,1278nm
H2O 1368.59nm,1392nm
NH3 1512nm
C2H2 1532.68nm
CO 1567nm
H2S 1578nm
Co2 1580nm,2.0um
C2H4 1620nm,1627nm
CH4 1647nm,1650.9nm,1653.7nm,1660nm
HCl 1742nm

Detailed External Dimensions:
Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
 
 
Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.
Dfb Laser Device, Butterfly Package, Precision Fiber Laser for Gas Testing.


Frequently Asked Questions

Q1: Is it possible to place a sample order? What is the minimum order quantity (MOQ)?

A1: Any interested party is warmly invited to initiate a sample order to thoroughly evaluate the exemplary quality.There is no MOQ; a single-piece sample is readily available.

Q2: What is the expected lead time?
A2: Typically, the lead time is approximately 1 week. For larger quantities and special products, please confirm the lead time with our sales representative.

Q3: What are the available payment options?
A3: We accept several payment methods: T/T, Paypal, Western Union, Cash, etc.

Q4: How long is your warranty period?
A4: Our products come with a 1-year warranty.

Q5: Is it possible to customize the logo, label, and packaging?
A5: Absolutely, we offer OEM services tailored to your specifications, including custom product labels, logos, PN, SN, and packaging.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier